Přejít k obsahu


Earthquake Load Effects on NPP Primary Circuit Pipelines

Citace: DEMJANČUKOVÁ, K. Earthquake Load Effects on NPP Primary Circuit Pipelines. Praha, 2013.
Druh: PŘEDNÁŠKA, POSTER
Jazyk publikace: eng
Anglický název: Earthquake Load Effects on NPP Primary Circuit Pipelines
Rok vydání: 2013
Autoři: Ing. Kateřina Demjančuková
Abstrakt EN: Historically, the safety of nuclear power plants (NPPs) is based on the ability to eliminate the large loss-of-coolant accident (large LOCA) which is represented by the double ended guillotine break of the primary circuit piping. As a matter of experience with operation of many nuclear units, US NRC prepared the so-called redefinition of large LOCA which is based on the theory of transition break size (TBS). For the PWR (Pressurized Water Reactor) the TBS is characterized by the piping with diameter of 360 mm. The license claimant has to prove that the postulated circumferential crack satisfies the requirements of ASME Code, Section XI.