Boost Power Factor Topology with Average Current Control

Citace:
MOLDASCHL, J., BROULÍM, J., PALOČKO, L. Boost Power Factor Topology with Average Current Control. In 2014 International Conference on Applied Electronics. Pilsen: University of West Bohemia, 2014. s. 213-216. ISBN: 978-80-261-0276-2 , ISSN: 1803-7232
Druh: STAŤ VE SBORNÍKU
Jazyk publikace: eng
Anglický název: Boost Power Factor Topology with Average Current Control
Rok vydání: 2014
Místo konání: Pilsen
Název zdroje: University of West Bohemia
Autoři: Ing. Jan Moldaschl , Ing. Jan Broulím , Ing. Lukáš Paločko ,
Abstrakt EN: This paper presents experimental results of a power factor corrector (PFC) with the average current control. Nowadays, we need a power factor corrector for most switch mode power supplies. Usually, a boost corrector with the average current control is used. The average current control offers good noise immunity, small input ripple and stability. Main paper goal was explaining average current shaping technique. We designed PFC with average current control and tested it in range 50 - 500 W. The experimental results proved benefits and drawbacks of this control technique.